Controller Display Messages

53

MSA1000 Controller User Guide

300 RECOVERY ROM
AUTOFLASH
STARTED

Informational

Indicates that the array

controller has detected that

the firmware’s backup

recovery ROM image is

invalid and is copying the

current active firmware

image into the backup

recovery ROM.

301 RECOVERY ROM
AUTOFLASH DONE

Informational

Indicates that the array

controller has successfully

completed the process of

copying the current active

firmware image into the

backup recovery ROM.

302 RECOVERY ROM
AUTOFLASH FAILED

Error

Indicates that the array

controller failed to copy the

current active firmware

image into the backup

recovery ROM. Recovery

ROM support is disabled.

Remove the failing

array

controller, wait 10 seconds,

and then reinsert the array

controller insuring that it is

fully seated in the chassis.

The ROM autoflash process

will be attempted again.

Should the issue persist

please contact HP support.

Table 3: LCD Message Descriptions

Message

Type

Description

Action