beautypg.com

HP StorageWorks 1000 Modular Smart Array User Manual

Page 45

background image

Controller Display Messages

45

MSA1000 Controller User Guide

73 CACHE
HARDWARE
BATTERIES
MISSING

Error

The cache memory does

not have its required

batteries attached to it.

If the failure has occurred

on the

standby

array

controller, then remove the

standby

array controller,

replace the cache modules,

wait 10 seconds, and then

reinsert the array controller

insuring that it is fully

seated in the chassis.

If the failure has occurred

on the

active

array

controller, then wait until

down-time is available.

Power off the MSA1000,

remove the array controller,

replace the cache modules,

and reinsert the array

controller insuring it is fully

seated in the chassis.

Should the issue persist

please contact HP support.

80 REPLACEMENT
DRIVE FOUND BOX
# BAY

Informational

A SCSI drive that was

previously missing or failed

has now been replaced

with a working SCSI drive.

81 SMART DRIVE
ALERT BOX #,
BAY

Informational

A SCSI drive may be close

to failing. This was

determined either by the

drive firmware itself using

SMART technology or by

the array controller using

monitor and performance

testing.

The drive should be

replaced as soon as

possible following the

guidelines in Appendix E,

“Recovering from Hard

Drive Failure” in this guide.

82 DRIVE HOT
ADDED BOX #,
BAY

Informational

A SCSI drive has been

added to the MSA1000 or

one of the storage

enclosures attached to it.

Table 3: LCD Message Descriptions

Message

Type

Description

Action