HP StorageWorks 1000 Modular Smart Array User Manual
Page 45
Controller Display Messages
45
73 CACHE
HARDWARE
BATTERIES
MISSING
Error
The cache memory does
not have its required
batteries attached to it.
If the failure has occurred
on the
standby
array
controller, then remove the
standby
array controller,
replace the cache modules,
wait 10 seconds, and then
reinsert the array controller
insuring that it is fully
seated in the chassis.
If the failure has occurred
on the
active
array
controller, then wait until
down-time is available.
Power off the MSA1000,
remove the array controller,
replace the cache modules,
and reinsert the array
controller insuring it is fully
seated in the chassis.
Should the issue persist
please contact HP support.
80 REPLACEMENT
DRIVE FOUND BOX
#
Informational
A SCSI drive that was
previously missing or failed
has now been replaced
with a working SCSI drive.
81 SMART DRIVE
ALERT BOX #
BAY
Informational
A SCSI drive may be close
to failing. This was
determined either by the
drive firmware itself using
SMART technology or by
the array controller using
monitor and performance
testing.
The drive should be
replaced as soon as
possible following the
guidelines in Appendix E,
“Recovering from Hard
Drive Failure” in this guide.
82 DRIVE HOT
ADDED BOX #
BAY
Informational
A SCSI drive has been
added to the MSA1000 or
one of the storage
enclosures attached to it.
Table 3: LCD Message Descriptions
Message
Type
Description
Action