beautypg.com

HP StorageWorks 1000 Modular Smart Array User Manual

Page 34

background image

Controller Display Messages

34

MSA1000 Controller User Guide

30 I2C READ
FAILURE device name>

Error

The MSA1000 has a

number of internal devices

that are accessed via an

I2C hardware bus. One of

these devices failed when

attempting to read from it.

Certain I2C devices are

considered critical and will

result in a failure of the

array controller while

others may result in some

loss of functionality (such

as lost display messages).

Should the issue persist

please contact HP support.

31 I2C WRITE
FAILURE device name>

Error

The MSA1000 has a

number of internal devices

that are accessed via an

I2C hardware bus. One of

these devices failed when

attempting to write to it.

Certain I2C devices are

considered critical and will

result in a failure of the

array controller while

others may result in some

loss of functionality (such

as lost display messages).

Should the issue persist

please contact HP support.

32 CHASSIS NVRAM
CONTENTS
CORRUPTED

Error

The MSA1000 has

non-volatile memory on it

that contains required

information which is

needed to operate. This

non-volatile memory

appears to be corrupted

and the information is not

valid. The MSA1000

cannot continue to operate

and will halt.

Please contact HP support.

40 BEGIN
REDUNDANCY
SUPPORT

Informational

The array controllers are

attempting to enter

redundant mode.

Table 3: LCD Message Descriptions

Message

Type

Description

Action