beautypg.com

HP StorageWorks 1000 Modular Smart Array User Manual

Page 43

background image

Controller Display Messages

43

MSA1000 Controller User Guide

71 SYSTEM HALTED
FOR CACHE ERROR

Error

This message is generated

if the user chooses to

ignore a critical cache error

condition. It is always

preceded by message #72

(although message #72 is

removed from the LCD

display once it has

accepted user input).

The

no

option will cause

the array controller to halt

itself, providing the user an

opportunity to resolve the

issue. Selecting the

yes

option will result in the

cache data being erased.

Operation of the array

controller will continue

normally.

Error

1.1

and

1.2

: There is

only one cache board in

the array controller at

present but it was

previously configured with

a second cache board that

is now missing (dual cache

module configuration).

Error

2.1

and

2.2

: A

second cache board that

contained valid data was

removed from its original

array controller and added

to this array controller

(dual cache module

configuration). Error

2.3

: A

cache board that

contained valid data was

removed from its original

array controller and added

to this array controller

(single cache module

configuration). Return all

cache boards to their

original array controllers.

Power up the systems

without allowing any host

I/O and wait for the cache

data to be written to the

drives. This will take a few

minutes after the systems

have finished the power on

sequence. The systems can

be powered off and cache

boards moved to their new

locations.

Table 3: LCD Message Descriptions

Message

Type

Description

Action