Controller Display Messages

56

MSA1000 Controller User Guide

401 STORAGE BOX
# FAN FAILED

Error

The specified storage

enclosure indicates that one

of its fans has failed. The

storage enclosure and any

devices in it may now be

susceptible to overheating

if corrective action is not

taken.

Check all fans and insure

they are operating. Any

failed fans should be

replaced.

402 STORAGE BOX
# FAN
DEGRADED

Error

The specified storage

enclosure indicates that one

of its fans is not operating

at full efficiency. The fan

may eventually fail.

Check all fans and insure

they are operating. Any

failed fans should be

replaced.

403 STORAGE BOX
# FAN HOT
INSERTED

Informational

The specified storage

enclosure indicates that a

fan has been added.

404 STORAGE BOX
# FAN HOT
REMOVED

Informational

The specified storage

enclosure indicates that a

fan has been removed.

405 STORAGE BOX
# TEMPERATURE
OK

Informational

The temperature sensor in

the storage enclosure

indicates that the

temperature is now back in

the normal operating

range.

406 STORAGE BOX
# OVERHEATING

Error

The temperature sensor in

the storage enclosure

indicates that the enclosure

is starting to exceed the

normal operating range.

Check all fans and insure

they are operating. Any

failed fans should be

replaced. Insure that there

are drive blank cartridges

in any empty drive bays in

the enclosure. If the

enclosure is an MSA1000

and only one array

controller is inserted, insure

that there are cover plates

installed in the empty array

controller bay and the fibre

bay in the chassis.

Table 3: LCD Message Descriptions

Message

Type

Description

Action