Controller Display Messages
56
401 STORAGE BOX
#
Error
The specified storage
enclosure indicates that one
of its fans has failed. The
storage enclosure and any
devices in it may now be
susceptible to overheating
if corrective action is not
taken.
Check all fans and insure
they are operating. Any
failed fans should be
replaced.
402 STORAGE BOX
#
DEGRADED
Error
The specified storage
enclosure indicates that one
of its fans is not operating
at full efficiency. The fan
may eventually fail.
Check all fans and insure
they are operating. Any
failed fans should be
replaced.
403 STORAGE BOX
#
INSERTED
Informational
The specified storage
enclosure indicates that a
fan has been added.
404 STORAGE BOX
#
REMOVED
Informational
The specified storage
enclosure indicates that a
fan has been removed.
405 STORAGE BOX
#
OK
Informational
The temperature sensor in
the storage enclosure
indicates that the
temperature is now back in
the normal operating
range.
406 STORAGE BOX
#
Error
The temperature sensor in
the storage enclosure
indicates that the enclosure
is starting to exceed the
normal operating range.
Check all fans and insure
they are operating. Any
failed fans should be
replaced. Insure that there
are drive blank cartridges
in any empty drive bays in
the enclosure. If the
enclosure is an MSA1000
and only one array
controller is inserted, insure
that there are cover plates
installed in the empty array
controller bay and the fibre
bay in the chassis.
Table 3: LCD Message Descriptions
Message
Type
Description
Action