beautypg.com

HP StorageWorks 1000 Modular Smart Array User Manual

Page 48

background image

Controller Display Messages

48

MSA1000 Controller User Guide

106 VOLUME #
STATE WAITING TO
REBUILD

Informational

The configured volume is

waiting to start rebuilding

data on a SCSI drive that

replaces a previously failed

drive. The rebuild may not

have started yet because

the array controller is

already performing a

rebuild on another

configured volume.

107 VOLUME #
STATE WAITING TO
EXPAND

Informational

The configured volume is

waiting to start a volume

expansion operation. The

expansion may have not

started yet because another

configured volume is

undergoing expansion or a

rebuild is occurring on the

configured volume.

108 VOLUME #
STATE MISSING
DRIVES

Error

The configured volume is

missing too many of the

SCSI drives that it is

composed of making it

unusable. The volume will

be disabled.

Power off the MSA1000

and then all attached

storage enclosures. Unplug

and reinsert all SCSI drives

insuring they are fully

seated in their bays. Check

the cables connecting the

MSA1000 to any attached

storage enclosures. Power

on the attached storage

enclosures and then the

MSA1000.

109 VOLUME #
STATE WRONG
DRIVE REPLACED

Error

The configured volume

appears to have had

known, good SCSI drives

replaced instead of known,

failed drives.

The MSA1000 should be

powered off and the good

drives should be restored

while the failed drives

should be replaced.

Table 3: LCD Message Descriptions

Message

Type

Description

Action