beautypg.com

HP XP P9500 Storage User Manual

Page 232

background image

Table 78 SSB codes that are returned by raidcom add rcu_path command (continued)

raidcom add rcu_path

Description

Error code

Executing/
Asynchronous

Error message

SSB2

SSB1

/Asynchronous

Get Command Status

The value of specified port is invalid.

8400

2E00

Executing

CMDRJE

/Asynchronous

Get Command Status

Failed to establish a path or the deletion operation. The following
factor can be thought.

3101

2E10

Asynchronous

Get Command Status

Input parameter is invalid.

Port status or the MP Blade status is in the state of abnormal.

Cable is not connected correctly.

Port is specified incorrectly.

The operation cannot be done because the microcode is being
changed.

8004

2E11

Asynchronous

Get Command Status

The command cannot be accepted. After a while, execute the
same command.

9400

2E11

Executing

CMDRJE

A logical path cannot be added because the specified RCU is
not registered.

3001

2E20

Asynchronous

Get Command Status

The specified CU number is not defined, or an LDEV is not
defined under the CU number.

7101

2E21

Asynchronous

Get Command Status

An RCU path cannot be added because the number of valid
paths exceeds the maximum.

3100

2E23

Asynchronous

Get Command Status

The port attribute is not Initiator (MCU).

840A

2E30

Executing

CMDRJE

Command cannot be executed because the RCU identification
code of a path is invalid.

3001

2E31

Asynchronous

Get Command Status

Command cannot be executed because the serial number is not
unified in the specified path.

3101

2E31

Asynchronous

Get Command Status

The command cannot be accepted. After a while, execute the
same command.

00EE

2ED6

Executing

CMDRJE

An internal error occurred.

3005

2ED6

Asynchronous

Get Command Status

Call HP Technical Support.

The value of SSID on the remote storage system is invalid.

3300

2ED6

Executing

CMDRJE

Table 79 SSB codes that are returned by raidcom delete rcu command

raidcom delete rcu

Description

Error code

Executing/
Asynchronous

Error message

SSB2

SSB1

CU# on the RCU exceeds the effective range.

3001

2E00

Executing

CMDRJE

Invalid product ID or path registration ID.

3005

2E00

Executing

CMDRJE

Command cannot be executed because the parameter of
specified RCU is invalid.

3008

2E00

Asynchronous

Get Command Status

The value of specified port# on the side of RCU is invalid.

3200

2E00

Executing

CMDRJE

232 Troubleshooting