HP XP P9500 Storage User Manual
Page 210

Table 53 SSB codes that are returned by raidcom add journal command (continued)
raidcom add journal
Description
Error code
Executing/
Asynchronous
Error message
SSB2
SSB1
The journal start threshold value, or the journal end threshold
value is incorrect.
500A
2E00
Asynchronous
Get Command Status
The specified CLPR number is incorrect.
7000
2E00
Asynchronous
Get Command Status
The specified cache value of a journal on the primary or the
secondary side is incorrect.
8101
2E00
Asynchronous
Get Command Status
The total cache amount is incorrect.
8102
2E00
Asynchronous
Get Command Status
The specified MP Blade ID is invalid.
8301
2E00
Executing
CMDRJE
The specified volume is already used by another program
product.
0000
2E10
Asynchronous
Get Command Status
The specified volume is not installed or cannot be used.
0011
2E10
Asynchronous
Get Command Status
The specified volume is connected from the mainframe host.
001A
2E10
Asynchronous
Get Command Status
There is a PIN slot in the journal volume.
001B
2E10
Asynchronous
Get Command Status
The specified volume cannot be registered as a journal volume
because it is in shredding. Wait until the shredding operation
is completed, then retry the operation.
001C
2E10
Asynchronous
Get Command Status
The specified operation failed because the journal or mirror is
not in the operable status.
5000
2E10
Asynchronous
Get Command Status
The operation cannot be done because it is in the state of
start-up.
800B
2E11
Asynchronous
Get Command Status
The operation cannot be done because the internal processing
is in progress. Wait for a while, then retry the operation.
800E
2E11
Asynchronous
Get Command Status
Abnormal cache status.
9400
2E11
Asynchronous
Get Command Status
The command cannot be accepted. After a while, execute the
same command.
9400
2E11
Executing
CMDRJE
The specified LDEV is not defined.
0000
2E20
Executing
CMDRJE
The specified MP Blade is not installed.
8300
2E20
Executing
CMDRJE
The operation failed because the specified journal is not
installed.
5000
2E21
Asynchronous
Get Command Status
The journal volume cannot be added, or the journal cannot be
added to the extended CT group due to insufficient capacity of
the shared memory (SM).
8104
2E21
Asynchronous
Get Command Status
The SM for Continuous Access Journal is not installed.
8105
2E21
Executing
CMDRJE
A journal volume cannot be registered, or a journal cannot be
added to the extended CT group because the program product
9000
2E21
Asynchronous
Get Command Status
of Continuous Access Journal or Continuous Access Journal Zis
not installed.
A new journal volume cannot be registered, or the number of
selected volumes is too many.
0005
2E23
Asynchronous
Get Command Status
The operation failed because the multiple LDKC numbers cannot
be mixed in the journal.
003E
2E23
Asynchronous
Get Command Status
The operation failed because the number of journals in the
journal or the extended CT group exceeds the maximum.
5000
2E23
Asynchronous
Get Command Status
210