HP XP P9500 Storage User Manual
Page 206
Table 50 SSB codes that are returned by raidcom modify port -security _switch command (continued)
raidcom modify port -security _switch
Description
Error code
Executing/
Asynchronous
Error message
SSB2
SSB1
The other than "fabric on" cannot be specified when specifying
a topology of the package for Fibre Channel over Ethernet.
05A6
B955
Executing
CMDRJE
The other than "P-to-P (point to point)" cannot be specified when
specifying a topology of the package for Fibre Channel over
Ethernet.
05A7
B955
Executing
CMDRJE
The command device being used at the local RAID Manager
exists under the port.
1039
B955
Executing
CMDRJE
The program product is not installed.
104F
B955
Executing
CMDRJE
Invalid host speed is set for the 4Gbps fibre adapter. The
available host speeds are AUTO, 1G, 2G, and 4G only.
113D
B955
Executing
CMDRJE
Invalid host speed is set for the 8Gbps fibre adapter. The
available host speeds are AUTO, 2G, 4G, and 8G only.
113F
B955
Executing
CMDRJE
The other than "10G" cannot be specified when specifying a
host speed of the package for Fibre Channel over Ethernet.
11A5
B955
Executing
CMDRJE
Table 51 SSB codes that are returned by raidcom add ldev command
raidcom add ldev
Description
Error code
Executing/
Asynchronous
Error message
SSB2
SSB1
It exceeds the range of LDEV number.
0000
2E00
Executing
CMDRJE
Cannot create because the specified capacity is invalid.
0002
2E00
Executing
CMDRJE
SSID is not in the effective range.
0003
2E00
Executing
CMDRJE
The value of specified emulation type is invalid.
000D
2E00
Executing
CMDRJE
The specified emulation type is not supported in this command.
000E
2E00
Executing
CMDRJE
The capacity in the case of specifying a emulation type of the
mainframe series must be dividable by the cylinder.
0019
2E00
Executing
CMDRJE
The capacity when 3390-V emulation type is specified must be
divisible by page unit.
001A
2E00
Executing
CMDRJE
When you specify emulation type for open system, you cannot
specify the size by the cylinder.
001C
2E00
Executing
CMDRJE
A volume for online data migration cannot be created because
the specified value of capacity (LBA) is not the maximum.
0025
2E00
Executing
CMDRJE
The capacity must be specified because LDEVs are in the parity
group (or the external volume group).
0026
2E00
Executing
CMDRJE
The capacity must be specified.
0027
2E00
Executing
CMDRJE
The parity group number or the external group number is not in
the effective range.
0101
2E00
Executing
CMDRJE
Failed to restore the LDEV that is created to external volume
group.
1005
2E00
Asynchronous
Get Command Status
The specified pool ID is not in the effective range.
6000
2E00
Executing
CMDRJE
The specified CLPR number is not in the effective range.
7000
2E00
Executing
CMDRJE
206 Troubleshooting