HP XP P9500 Storage User Manual
Page 212
Table 53 SSB codes that are returned by raidcom add journal command (continued)
raidcom add journal
Description
Error code
Executing/
Asynchronous
Error message
SSB2
SSB1
The specified LDEV cannot be operated because it is an external
volume mapped for online data migration.
0074
2E30
Asynchronous
Get Command Status
The command cannot be accepted. After a while, execute the
same command.
08E6
2EE4
Executing
CMDRJE
An internal error occurred.
50EE
2EE4
Asynchronous
Get Command Status
Call HP Technical Support.
An internal error occurred.
FEEC
2EE4
Executing
CMDRJE
Call HP Technical Support.
Asynchronous
Get Command Status
Table 54 SSB codes that are returned by raidcom modify journal command
raidcom modify journal
Description
Error code
Executing/
Asynchronous
Error message
SSB2
SSB1
The specified volume capacity is too small.
0023
2E00
Executing
CMDRJE
The specified path block watch time exceeds the range.
500B
2E00
Executing
CMDRJE
The specified MP Blade ID is invalid.
8301
2E00
Executing
CMDRJE
The specified volume is not installed or cannot be used.
0011
2E10
Executing
CMDRJE
The specified operation failed because the journal or mirror is
not in the operable status.
5000
2E10
Executing
CMDRJE
The specified operation failed because the mirror of journal is
not in the operable status.
5006
2E10
Executing
CMDRJE
The specified MP Blade is blocked.
8300
2E10
Executing
CMDRJE
The operation cannot be done because it is in the state of
start-up.
800B
2E11
Executing
CMDRJE
The specified journal ID is not registered.
5000
2E20
Executing
CMDRJE
The operation failed because the specified journal is not
registered.
5000
2E21
Executing
CMDRJE
The journal volume cannot be added, or the journal cannot be
added to the extended CT group due to insufficient capacity of
the shared memory (SM).
8104
2E21
Executing
CMDRJE
The specified volume cannot be used as a journal volume
because it is an external volume that can execute the I/O
suppression mode.
0062
2E30
Asynchronous
Get Command Status
The timer type cannot be changed because the specified journal
belongs to the extended CT group.
5001
2E30
Executing
CMDRJE
The parameter of inflow control cannot be changed because
the specified journal is not a primary journal.
5003
2E30
Executing
CMDRJE
The cache mode option or the data overflow monitoring time
cannot be changed because the specified journal is used by
both the primary and the secondary journals.
5005
2E30
Executing
CMDRJE
An internal error occurred.
50EE
2EE4
Executing
CMDRJE
212