Table 53 SSB codes that are returned by raidcom add journal command (continued)

raidcom add journal

Description

Error code

Executing/
Asynchronous

Error message

SSB2

SSB1

The specified LDEV cannot be operated because it is an external
volume mapped for online data migration.

0074

2E30

Asynchronous

Get Command Status

The command cannot be accepted. After a while, execute the
same command.

08E6

2EE4

Executing

CMDRJE

An internal error occurred.

50EE

2EE4

Asynchronous

Get Command Status

Call HP Technical Support.

An internal error occurred.

FEEC

2EE4

Executing

CMDRJE

Call HP Technical Support.

Asynchronous

Get Command Status

Table 54 SSB codes that are returned by raidcom modify journal command

raidcom modify journal

Description

Error code

Executing/
Asynchronous

Error message

SSB2

SSB1

The specified volume capacity is too small.

0023

2E00

Executing

CMDRJE

The specified path block watch time exceeds the range.

500B

2E00

Executing

CMDRJE

The specified MP Blade ID is invalid.

8301

2E00

Executing

CMDRJE

The specified volume is not installed or cannot be used.

0011

2E10

Executing

CMDRJE

The specified operation failed because the journal or mirror is
not in the operable status.

5000

2E10

Executing

CMDRJE

The specified operation failed because the mirror of journal is
not in the operable status.

5006

2E10

Executing

CMDRJE

The specified MP Blade is blocked.

8300

2E10

Executing

CMDRJE

The operation cannot be done because it is in the state of
start-up.

800B

2E11

Executing

CMDRJE

The specified journal ID is not registered.

5000

2E20

Executing

CMDRJE

The operation failed because the specified journal is not
registered.

5000

2E21

Executing

CMDRJE

The journal volume cannot be added, or the journal cannot be
added to the extended CT group due to insufficient capacity of
the shared memory (SM).

8104

2E21

Executing

CMDRJE

The specified volume cannot be used as a journal volume
because it is an external volume that can execute the I/O
suppression mode.

0062

2E30

Asynchronous

Get Command Status

The timer type cannot be changed because the specified journal
belongs to the extended CT group.

5001

2E30

Executing

CMDRJE

The parameter of inflow control cannot be changed because
the specified journal is not a primary journal.

5003

2E30

Executing

CMDRJE

The cache mode option or the data overflow monitoring time
cannot be changed because the specified journal is used by
both the primary and the secondary journals.

5005

2E30

Executing

CMDRJE

An internal error occurred.

50EE

2EE4

Executing

CMDRJE