Ssb code returned by a replication command – HP XP P9500 Storage User Manual
Page 198
SSB code returned by a replication command
When one of the replication commands returns an SSB code, refer to the troubleshooting information
in the manual corresponding to the product in which it occurs.
Product returning the SSB code
Command
Continuous Access Synchronous
•
paircreate
•
pairresync
•
pairsplit
•
horctakeover
•
horctakeoff
Continuous Access Journal
•
paircreate
•
pairresync
•
pairsplit
•
horctakeover
•
horctakeoff
Business Copy
•
paircreate
•
pairresync
•
pairsplit
Database Validator
•
raidvchkset -vt
•
raidvchkset -vs
Data Retention
raidvchkset -vg
Thin Provisioning
•
raidvchkset -vext
SSB code returned by the configuration setting command (raidcom command)
Executing the configuration setting command (raidcom command) may return an SSB code. An
error may occur whether the command is executed synchronously or asynchronously. For an
asynchronous error, the error information is displayed on the console by executing raidcom get
command_status command. When the error message shows "CMDRJE" or "Get Command Status",
check the contents of SSB1 and SSB2. You can verify a content of an error by the raidcom get
error_message command. When you specify the SSB code with the raidcom get error_message
command, make sure not to specify a wrong SSB code.
The following tables show lists information about each SSB code returned by the configuration
setting command (raidcom command). If you see an error not described in the tables, contact HP
Technical Support.
198 Troubleshooting