beautypg.com

HP XP P9500 Storage User Manual

Page 221

background image

Table 67 SSB codes that are returned by raidcom delete lun command (continued)

raidcom delete lun

Description

Error code

Executing/
Asynchronous

Error message

SSB2

SSB1

Another LDEV is already mapped in the specified LUN.

09A1

B958

Executing

CMDRJE

The command device is being used in the local RAID Manager.

B9F9

B9F9

Executing

CMDRJE

Table 68 SSB codes that are returned by raidcom add lun command

raidcom add lun

Description

Error code

Executing/
Asynchronous

Error message

SSB2

SSB1

An invalid LDEV exists in the specified LDEVs.

0014

2EF6

Executing

CMDRJE

LUN path cannot be set because it is reserved for Auto LUN.

0101

B958

Executing

CMDRJE

The attribute of the specified port is Initiator or External.

0150

B958

Executing

CMDRJE

The other than HMDE volume or OPEN volume is included in
the specified LDEV.

0155

B958

Executing

CMDRJE

An LU path has already defined in the relevant LDEV.

015A

B958

Executing

CMDRJE

An invalid LDEV exists in the specified LDEVs.

015D

B958

Executing

CMDRJE

It exceeds the maximum LUN under the port.

015E

B958

Executing

CMDRJE

LDEV is set as a pool volume.

0178

B958

Executing

CMDRJE

LUN path cannot be set because the LDEV is a system disk.

017B

B958

Executing

CMDRJE

LUN path cannot be set because the LDEV is a journal volume.

017C

B958

Executing

CMDRJE

LUN path cannot be set because the access attribute of LDEV
Data Retention is reserved.

017D

B958

Executing

CMDRJE

LUN path cannot be set because the access attribute of LEV Data
Retention is different with the R/W permissions.

017E

B958

Executing

CMDRJE

When the host mode is External Storage(0x4C), the LUN path
cannot be set in the other than the external volume.

01A3

B958

Executing

CMDRJE

The LU path definition cannot be set because it specifies more
than one different resource groups.

01F2

B958

Executing

CMDRJE

Command device cannot be set because it is reserved for Auto
LUN.

0601

B958

Executing

CMDRJE

Command device cannot be set because it is an Business Copy
pair/or it is reserved.

0606

B958

Executing

CMDRJE

The command device cannot be released because it is used at
the local RAID Manager.

0639

B958

Executing

CMDRJE

A command device cannot be set because LDEV is other than
the OPEN volume.

064A

B958

Executing

CMDRJE

The specified LDEV is not installed.

065D

B958

Executing

CMDRJE

A command device cannot be set because LDEV is the virtual
volume of Snapshot.

0679

B958

Executing

CMDRJE

The value of LUN exceeds the maximum.

0944

B958

Executing

CMDRJE

The value of LDEV exceeds the maximum.

0945

B958

Executing

CMDRJE

Error messages and error codes 221