HP XP P9500 Storage User Manual
Page 221
Table 67 SSB codes that are returned by raidcom delete lun command (continued)
raidcom delete lun
Description
Error code
Executing/
Asynchronous
Error message
SSB2
SSB1
Another LDEV is already mapped in the specified LUN.
09A1
B958
Executing
CMDRJE
The command device is being used in the local RAID Manager.
B9F9
B9F9
Executing
CMDRJE
Table 68 SSB codes that are returned by raidcom add lun command
raidcom add lun
Description
Error code
Executing/
Asynchronous
Error message
SSB2
SSB1
An invalid LDEV exists in the specified LDEVs.
0014
2EF6
Executing
CMDRJE
LUN path cannot be set because it is reserved for Auto LUN.
0101
B958
Executing
CMDRJE
The attribute of the specified port is Initiator or External.
0150
B958
Executing
CMDRJE
The other than HMDE volume or OPEN volume is included in
the specified LDEV.
0155
B958
Executing
CMDRJE
An LU path has already defined in the relevant LDEV.
015A
B958
Executing
CMDRJE
An invalid LDEV exists in the specified LDEVs.
015D
B958
Executing
CMDRJE
It exceeds the maximum LUN under the port.
015E
B958
Executing
CMDRJE
LDEV is set as a pool volume.
0178
B958
Executing
CMDRJE
LUN path cannot be set because the LDEV is a system disk.
017B
B958
Executing
CMDRJE
LUN path cannot be set because the LDEV is a journal volume.
017C
B958
Executing
CMDRJE
LUN path cannot be set because the access attribute of LDEV
Data Retention is reserved.
017D
B958
Executing
CMDRJE
LUN path cannot be set because the access attribute of LEV Data
Retention is different with the R/W permissions.
017E
B958
Executing
CMDRJE
When the host mode is External Storage(0x4C), the LUN path
cannot be set in the other than the external volume.
01A3
B958
Executing
CMDRJE
The LU path definition cannot be set because it specifies more
than one different resource groups.
01F2
B958
Executing
CMDRJE
Command device cannot be set because it is reserved for Auto
LUN.
0601
B958
Executing
CMDRJE
Command device cannot be set because it is an Business Copy
pair/or it is reserved.
0606
B958
Executing
CMDRJE
The command device cannot be released because it is used at
the local RAID Manager.
0639
B958
Executing
CMDRJE
A command device cannot be set because LDEV is other than
the OPEN volume.
064A
B958
Executing
CMDRJE
The specified LDEV is not installed.
065D
B958
Executing
CMDRJE
A command device cannot be set because LDEV is the virtual
volume of Snapshot.
0679
B958
Executing
CMDRJE
The value of LUN exceeds the maximum.
0944
B958
Executing
CMDRJE
The value of LDEV exceeds the maximum.
0945
B958
Executing
CMDRJE
Error messages and error codes 221