Table 43 VCEM server error messages and descriptions (continued)
Error message description
NOTE:
The error message descriptions in this table use
[x] to represent variables in the error message output.
Error message number
xx-xx-xx-xx-xx-xx-xx-xx, or xxxxxxxxxxxxxxxx, where each
x is a hexadecimal digit.
In the FCoE connection for port number and interconnect
bay , the specified boot target LUN is missing or invalid.
2763
Valid values are either a 3-digit decimal between 0 and
255, or a 13- to 16-digit hexadecimal between 0 and
FFFFFFFFFFFFFFFF.
Cannot create FCoE connection because the maximum
number of FCoE connections was reached.
2764
Cannot remove FCoE connection because the Server Profile
does not have a FCoE connection.
2765
Cannot find FCoE connection for the specified interconnect
bay because the interconnect bay number is invalid or
there is not a FCoE connection for this interconnect bay.
2766
In the FCoE connection for port number and interconnect
bay , the custom port speed exceeds the maximum allowed
port speed ({2}Gb).
2767
In the Ethernet connection for port , the port speed is
incorrect. The minimum and maximum must be the same
when connection speed type is Custom.
2768
VCEM cannot update server profile . The connection bay
was changed.
2769
VCEM cannot update server profile . The connection port
number is duplicated.
2770
There are conflicting boot configuration types defined in
this profile (FC and FCoE). A Server Profile can have only
one boot configuration type specified.
2773
There are conflicting boot configuration types defined in
this profile (FC and iSCSI). A Server Profile can have only
one boot configuration type specified.
2774
There are conflicting boot configuration types defined in
this profile (FCoE and iSCSI). A Server Profile can have
only one boot configuration type specified.
2775
A Server Profile does not support more than two configured
Boot Setting parameters in Flex-10 iSCSI connections. The
2776
additional Flex-10 iSCSI connections 'Boot Settings'
parameters must be set to 'Disabled' value.
Cannot perform Server Profile operation because the VC
domain group does not support adding iSCSI connections.
2778
Cannot perform Server Profile operation because the VC
domain group does not support adding FCoE connections.
2779
VCEM cannot update Server Profile. The connection port
number is not arranged in order.
2781
VCEM cannot update Server Profile. The connection port
number is out of supported port range.
2782