beautypg.com

Add enet-connection, Syntax, Parameters – HP Insight Management-Software User Manual

Page 31

background image

add enet-connection

The -add enet-connection command adds a new Ethernet network connection to an existing
server profile in the VC domain.

NOTE:

The maximum number of Ethernet connections that can be added to a server profile

depends on the Virtual Connect firmware version. For more information, see the HP Virtual Connect
Enterprise Manager User Guide
available at:

http://www.hp.com/go/vcem/

.

Syntax

-add enet-connection –profilename
[[-mcastfilter ]|
[-mcastfilterset ]]
[-network ]
[–pxe ]
[–speedtype ]
[–speed ]

Parameters

Table 10 Parameter descriptions for -add enet-connection

Optional

Required

Description

Parameter

x

Name of an existing
multicast filter associated
with the connection

-mcastfilter

NOTE:

The

-mcastfilter

and

-mcastfilterset
parameters are optional.
You can omit them, or
specify one or the other. You
cannot specify both
-mcastfilter

and

-mcastfilterset
together.

x

Name of an existing
multicast filter set associated
with the connection

-mcastfilterset

x

Specifies the name of an
existing profile to which the
connection is added.

-profilename

x

Specifies the name of an
existing network to associate

-network

with the connection. If the
network name is not
specified or is set to
unassigned

, the network

will be left unassigned and
can be assigned later.

x

Enables or disables Preboot
Execution Environment (PXE)

-pxe

on the network connection.
If this value is not specified,
the default will be usebios.

NOTE:

Only one

connection can have PXE
enabled per profile.

add enet-connection

31

This manual is related to the following products: