Table 43 VCEM server error messages and descriptions (continued)

Error message description

NOTE:

The error message descriptions in this table use

[x] to represent variables in the error message output.

Error message number

In the ethernet connection for port , the port speed is
incorrect. Unassigned ethernet connections must have port
speed set to Preferred.

2660

In the Ethernet connection for port , the port speed is
incorrect. The minimum and maximum port speeds cannot

2661

be empty. The minimum must be lower than or equal to the
maximum, and the values must be a multiple of 100 Mb.

In the ethernet connection for port , the port speed exceeds
the maximum allowed port speed for the selected network
(Gb).

2662

In the ethernet connection for port , the port speed is below
the minimum allowed port speed for the selected network
(Gb).

2663

The provided port speed value is not a valid number.

2664

In the FC SAN connection for port number and interconnect
bay , the maximum number of boot configurations was
exceeded.

2674

In the FC SAN connection for port number and interconnect
bay , the specified boot target LUN is invalid. Valid value
is a 3-digit decimal between 0 and 255.

2675

In the FC SAN connection for port number and interconnect
bay , the selected FC SAN fabric does not exist. The FC

2676

SAN fabric must exist in the VC domain group the Server
Profile belongs.

In the FC SAN connection for port number and interconnect
bay , the selected port speed is invalid.

2677

In the FC SAN connection for port number and interconnect
bay , the specified boot target WWPN is not well-formed.

2678

Valid formats are xx:xx:xx:xx:xx:xx:xx:xx.
xx-xx-xx-xx-xx-xx-xx-xx, or xxxxxxxxxxxxxxxx, where each
x is a hexadecimal digit.

In the FC SAN connection for port number and interconnect
bay , the specified boot target LUN is invalid. Valid values

2679

are either a 3-digit decimal between 0 and 255, or a 13
to 16-digit hexadecimal between 0 and FFFFFFFFFFFFFFFF.

In the FC SAN connection for port number and interconnect
bay , the selected FC SAN fabric does not have a physical
connection to this port.

2680

Invalid number of WWN addresses in the FC SAN
connection for interconnect bay . VCEM does not support

2681

multiple WWPN addresses per physical port when using
Factory-Default WWN addresses.

Missing base initiator configuration in FC SAN connection
for interconnect bay .

2682

Cannot perform server profile assignment because bay {0}
is an auxiliary server blade.

2683

Cannot assign server profile because the selected bay is
covered.

2684