set fcoe-connection

The -set fcoe-connection command modifies an existing FCoE connection.

Syntax

set fcoe-connection –profilename
-portnumber
[[-fabric ] | [–fcoenetwork ]]
[-speedtype <1Gb|2Gb|4Gb|8Gb|Custom|Disabled>]
[–customspeed <100–10000>]
[–bootpriority ]
[–bootport ]
[–bootlun ]

Parameters

Table 17 Parameter descriptions for -set fcoe-connection

Optional

Required

Description

Parameter

x

Specifies the name of the
profile to which the FcOE
connection will be assigned.

-profilename

x

Specifies the port number of
the connection.

-portnumber

x

Specifies the name of the
FCoE SAN fabric to

-fabric

associate with the
connection.

x

Name of an existing FCoE
network associated with the
connection.

NOTE:

You cannot specify

both Fabric and
FcoeNetwork properties. If
neither property is specified,
the connection is marked as
Unassigned but associated
with a specific bay.

-fcoenetwork

x

Specifies the requested
operational speed for the

-speedtype

server port. Valid values
include 1Gb, 2Gb, 4Gb,
8Gb

, auto, custom,

disabled

, and

preferred

. If the speed

type is custom, you can
configure any speed from
100 Mb to 10 Gb in 100
Mb increments. The
-customspeed

parameter

is required if the speed type
is custom and is the
user-defined speed for the
server port. Valid values
include 100 Mb to 10 Gb
configured in 100 Mb
increments. The acceptable
value is 100 Mb/s to
10,000 Mb/s.