49 Redundancy Failed Firmware Lockup
Type: Error
Description: While either attempting to enter redundant mode or already
operating in redundant mode, one of the controllers encountered a critical
condition resulting in a firmware lockup. Redundancy is disabled at this time.
Action:
If the storage system is currently involved in host I/O:
1. Remove the standby controller.
2. Wait 10 seconds.
3. Reinstall the controller, and be sure that it seats fully in the chassis.
If this action does not solve the problem, wait until downtime is available and do
the following:
1. Power down the storage system (on page
2. Remove both controllers.
3. Reinstall both controllers, and be sure that they seat fully in the chassis.
If this action does not solve the problem, contact HP support.
50 Redundancy Failed Out of Memory
Type: Error
Description: While either attempting to enter redundant mode or already
operating in redundant mode, one of the controllers failed to allocate required
memory. Redundancy is disabled at this time.
Action:
If the storage system is currently involved in host I/O:
1. Remove the standby controller.