Troubleshooting

105

69 Cache Batteries Low, Recharging

Type: Informational

Description: The batteries on the cache module are low; the storage system is
recharging the batteries.

Action: None

70 Cache Disabled No Configuration

Type: Informational

Description: The controller has disabled the cache because the cache is not
configured.

Action: Use ACU to configure the cache.

71 System Halted for Cache Error

Type: Error

Description: The user has chosen to address a critical cache error condition. This
message always appears after message 72 ("72 Cache Error Ignore>? <=NO
>=YES" on page

106

). Message 72 is removed from the LCD after it has

accepted user input.

Action:

• Select the NO option to halt the controller and solve the problem.
• Select the YES option to erase the cache data. Operation of the controller

continues normally.

Error 1.1 and 1.2: Only one cache board is in the controller, but the controller
was configured with a second cache board that is missing (dual cache module
configuration).