beautypg.com

102 volume # state interim recovery, 103 volume # state rebuilding, 104 volume # state disabled – HP StorageWorks 500 G2 Modular Smart Array User Manual

Page 112

background image

112

HP StorageWorks MSA500 G2 Storage System User Guide

102 Volume # State Interim Recovery

Type: Informational

Description: The controller failed one or more of the physical drives that
constitute the configured volume. No data loss has occurred because fault
tolerance is allowing data recovery.

Action: Replace the failed drive or drives as soon as possible ("Recognizing hard
drive failure" on page

78

).

103 Volume # State Rebuilding

Type: Informational

Description: The configured volume is rebuilding data on a physical drive that
replaced a previously failed drive.

Action: None

104 Volume # State Disabled

Type: Error

Description: The controller disabled the configured volume because too many
drives that constitute the volume are missing.

Action:

1. Power down the storage system (on page

28

).

2. Power down all attached storage enclosures.

3. Remove and reinstall all SCSI drives, and be sure that they seat fully in their

bays.

4. Check for proper connections on the cables to and from the MSA500 G2

storage system.

5. Power up the attached storage enclosures.