HP StorageWorks MSA500 G2 Storage System User Guide

86 Drive Position Change Detected

Type: Informational

Description: The physical drive locations have changed for SCSI drives that
constitute a configured volume within the MSA500 G2 storage system. The
controller can no longer access the configured volume.

Action: None

87 Drive Position Change Invalid

Type: Informational

Description: The physical drive locations have changed for SCSI drives that
constitute a configured volume within the MSA500 G2 storage system. The
controller can no longer access the configured volume.

Action:

1. Power down the storage system (on page

28

).

2. Restore the drives to their original positions.

If this action does not solve the problem, contact HP support.

89 Invalid Volume Addition

Type: Error

Description: The controller has detected an illegal volume addition.

Action: Remove the added volume.