beautypg.com
6
HP StorageWorks MSA500 G2 Storage System User Guide
31 I2C Write Failure .............................................................................. 93
32 Chassis NVRAM Contents Corrupted ............................................................................... 93
40 Begin Redundancy Support ............................................................................................... 94
41 Redundancy Active Active Controller............................................................................... 94
42 Redundancy Active Standby Controller ............................................................................ 94
43 Redundancy Failed Hardware Failure ............................................................................... 95
44 Redundancy Failed Mismatch Hardware........................................................................... 96
45 Redundancy Failed Mismatch Hardware........................................................................... 96
47 Redundancy Failed Cache Size Mismatch......................................................................... 97
48 Redundancy Halted Firmware Cloned............................................................................... 97
49 Redundancy Failed Firmware Lockup............................................................................... 98
50 Redundancy Failed Out of Memory .................................................................................. 98
51 Redundancy Failed I/O Request Error ............................................................................... 99
52 Redundancy Failed PCI Bus Error................................................................................... 100
53 Redundancy Failed No Second Controller....................................................................... 100
54 Redundancy Failed Cache DIMMs Mismatch................................................................. 101
60 No Cache Module Found................................................................................................. 101
61 Dual Cache Module Size Mismatch ................................................................................ 102
62 Cache Module # MB........................................................................................... 102
63 Valid Cache Data Found at Power-Up............................................................................. 102
64 Cache Data Lost Battery Dead......................................................................................... 103
65 Cache Hardware Enabled ................................................................................................ 103
66 Cache Hardware Failed and Disabled.............................................................................. 103
67 Cache Hardware Temporarily Disabled........................................................................... 104
68 Obsolete Cache Data Deleted .......................................................................................... 104
69 Cache Batteries Low, Recharging ................................................................................... 105
70 Cache Disabled No Configuration ................................................................................... 105
71 System Halted for Cache Error ........................................................................................ 105
72 Cache Error Ignore>? <=NO >=YES....................................................................... 106
73 Cache Hardware Batteries Missing.................................................................................. 107
80 Replacement Drive Found Box # Bay ............................................................... 108
81 Smart Drive Alert Box #, Bay ............................................................................ 108
82 Drive Hot Added Box #, Bay ............................................................................. 108
83 Drive Hot Removed Box #, Bay ........................................................................ 109
84 Drive Failure Box #, Bay ................................................................................... 109
85 Bad Drive Failure Box #, Bay ............................................................................ 109
86 Drive Position Change Detected...................................................................................... 110
87 Drive Position Change Invalid......................................................................................... 110
89 Invalid Volume Addition ................................................................................................. 110
90 RIS Version Exceeded ..................................................................................................... 111
100 Volume # State OK ................................................................................................. 111
101 Volume # State Failed ............................................................................................. 111
102 Volume # State Interim Recovery ........................................................................... 112
103 Volume # State Rebuilding ..................................................................................... 112
104 Volume # State Disabled......................................................................................... 112