beautypg.com

407 storage box # overheated, 408 storage box # power supply ok, 409 storage box # power supply failed – HP StorageWorks 500 G2 Modular Smart Array User Manual

Page 127

background image

Troubleshooting

127

407 Storage Box # Overheated

Type: Error

Description: The temperature sensor in the specified storage system indicates
that the temperature exceeded the normal operating range.

Action:

1. Avoid hardware failure. Power down the storage system (on page

28

).

2. Be sure that all MSA500 G2 storage system fans are operating.

3. Replace any failed fans.

4. Be sure that all bays are populated with components or blanks.

If this action does not solve the problem, contact HP support.

408 Storage Box # Power Supply OK

Type: Informational

Description: The specified storage system indicates that one of its previously
failed power supplies is now operating normally.

Action: None

409 Storage Box # Power Supply Failed

Type: Error

Description: The specified storage system indicates that one of its power
supplies has failed.

Action:

1. Check all power supplies for damage.

2. Replace any failed power supplies.