beautypg.com

108 volume # state missing drives, 109 volume # state wrong drive replaced – HP StorageWorks 500 G2 Modular Smart Array User Manual

Page 114

background image

114

HP StorageWorks MSA500 G2 Storage System User Guide

108 Volume # State Missing Drives

Type: Error

Description: The configured volume is unusable because too many drives that
constitute the volume are missing. The controller will disable this volume.

Action:

1. Power down the storage system (on page

28

).

2. Power down all attached storage enclosures.

3. Remove and reinstall all SCSI drives, and be sure that they seat fully in their

bays.

4. Check for proper connections on the cables to and from the MSA500 G2

storage system.

5. Power up the attached storage enclosures.

6. Power up the storage system (on page

27

).

If this action does not solve the problem, contact HP support.

109 Volume # State Wrong Drive Replaced

Type: Error

Description: The controller recognizes drive replacement on working physical
drives rather than failed drives.

Action:

1. Power down the storage system (on page

28

).

2. Reinstall the working drives.

3. Replace the failed drives.

4. Power up the storage system (on page

27

).