06 restarting system, 07 clone firmware? '<'=no, '>'=yes, 08 firmware flash failed – HP StorageWorks 500 G2 Modular Smart Array User Manual
Page 91

Troubleshooting
91
06 Restarting System
Type: Informational
Description: Indicates that the system has been reset and is being restarted.
Action: None
07 Clone Firmware? '<'=NO, '>'=YES
Type: User Input
Description: The controller is attempting to enter redundant mode but needs to
clone the firmware. The controller is requesting confirmation from the user to
overwrite the current firmware with the version from the redundant controller.
Action:
• If the user selects YES, the firmware is cloned.
• If the user selects NO, the firmware disables the controller.
• If the user does not respond within 60 seconds, the controller does the
following:
– In a non-hot-plug environment, the controller with the most recent
firmware disables the controller with the older firmware and continues the
power-up sequence. This method prevents automatic loss of a previous
version of firmware.
– In a hot-plug environment, cloning begins automatically, and the storage
system overwrites one firmware version with the other version.
08 Firmware Flash Failed
Type: Error
Description: The active controller was unable to clone the firmware onto a
redundant controller after two consecutive attempts.