HP StorageWorks MSA500 G2 Storage System User Guide

300 Recovery ROM Autoflash Started.......................................................................................

120

301 Recovery ROM Autoflash Done .........................................................................................

121

302 Recovery ROM Autoflash Failed ........................................................................................

121

303 ROM Cloning Started..........................................................................................................

121

304 ROM Cloning Done.............................................................................................................

122

305 ROM Cloning Failed ...........................................................................................................

122

306 Firmware Flash Started........................................................................................................

122

307 Firmware Flash Done ..........................................................................................................

123

308 Firmware Flash Failed .........................................................................................................

123

309 EMU Flash Started ..............................................................................................................

123

310 EMU Flash Done .................................................................................................................

124

311 EMU Flash Failed................................................................................................................

124

400 Storage Box # Fan OK ..................................................................................................

124

401 Storage Box # Fan Failed..............................................................................................

125

402 Storage Box # Fan Degraded ........................................................................................

125

403 Storage Box # Fan Hot Inserted ....................................................................................

125

404 Storage Box # Fan Hot Removed..................................................................................

126

405 Storage Box # Temperature OK....................................................................................

126

406 Storage Box # Overheating ...........................................................................................

126

407 Storage Box # Overheated ............................................................................................

127

408 Storage Box # Power Supply OK..................................................................................

127

409 Storage Box # Power Supply Failed .............................................................................

127

410 Storage Box # Power Supply Added.............................................................................

128

411 Storage Box # Power Supply Removed ........................................................................

128

412 Storage Box # EMU Not Responding ...........................................................................

128

413 Storage Box # EMU Version .......................................................................

129

500 Initializing PCI Subsystem ..................................................................................................

129

501 PCI Subsystem Hardware Failure........................................................................................

129

502 PCI Bridge ASIC Self Test Failure .....................................................................................

129

513 Uncorrected ECC Memory Error Seen................................................................................

130

518 Connection Lost ....................................................................................................

130

519 Connection Restored .............................................................................................

130

520 Unknown I/O Module Detected...........................................................................................

131

521 ULTRA 3 I/O Module Detected ..........................................................................................

131

Box numbering

The display message may specify a box number. Box 1 is the MSA500 G2
storage system.