404 Storage Box # Fan Hot Removed

Type: Informational

Description: The specified storage system indicates that a fan was removed.

Action: None

405 Storage Box # Temperature OK

Type: Informational

Description: The temperature sensor in the specified storage system indicates
that the temperature is in the normal operating range.

Action: None

406 Storage Box # Overheating

Type: Error

Description: The temperature sensor in the specified storage system indicates
that the temperature is exceeding the normal operating range.

Action:

1. Avoid hardware failure. Power down the storage system (on page

28

).

2. Be sure that all MSA500 G2 storage system fans are operating.

3. Replace any failed fans.

4. Be sure that all bays are populated with components or blanks.

If this action does not solve the problem, contact HP support.