Displaying information about pairs: flashcpy query – HP XP P9500 Storage User Manual
Page 69
Table 39 Information displayed by the FCQUERY command (continued)
Definition
Displayed
content
Displayed item
The relationship is established between the two Cnt Ac-S Z R-VOLs with the
Preserve Mirror FlashCopy function.
S
The relationship is in the status where the type of the Preserve Mirror FlashCopy
function (Preferred or Required) cannot be identified because the M-VOL and
R-VOL of Cnt Ac-S Z are mixed.
U
The number of tracks in the relationship.
-
NO. OF TRACKS
Displays the number of tracks that have not been copied.
-
TRACKS TO COPY
Using ICKDSF to view relationship states of Compatible FlashCopy
The following table shows the parameters you can use with the ICKDSF command.
Table 40 Parameters for the ICKDSF command
Description
Value
Parameter
Command
Sets the JCL statement identifying the volume. If the OS of the host
server is MVS, this parameter or the UNITADDRESS parameter is
required.
JCL statement
DDNAME or DNAME
FLASHCPY
QUERY
Sets the SYSNAME in the ASSGN system control statement. If the
OS of the host server is VSE, this parameter is required.
SYSNAME
SYSNAME
Specifies the device number (device address) of the S-VOL on which
you want to perform the FLASHCPY QUERY command. If the OS of
Source device
number
UNITADDRESS,
UNITADDR, or UNIT
the host server is MVS, this parameter or the DDNAME parameter
is required.
Specifies the CU number, the LDEV number, or the device number
of the S-VOL when you use the Remote FlashCopy function.
CU number
LDEV number
SOURCEVOL or
SRCVOL
Source device
number
Sets the JCL statement identifying the volume. If the OS of the host
server is MVS, this parameter or the UNITADDRESS parameter is
required.
JCL statement
DDNAME or DNAME
FLASHCPY
QUERY
RELATIONS
Sets the SYSNAME in the ASSGN system control statement. If the
OS of the host server is VSE, this parameter is required.
SYSNAME
SYSNAME
Specifies the device number (device address) of the S-VOL on which
you want to perform the FLASHCPY QUERY command. If the OS of
Source device
number
UNITADDRESS,
UNITADDR, or UNIT
the host server is MVS, this parameter or the DDNAME parameter
is required.
Displaying information about pairs: FLASHCPY QUERY
To display information about a Compatible FlashCopy pair, execute the ICKDSF FLASHCPY
QUERY
command. See the following example:
FLASHCPY QUERY UNIT(X'7000')
The following is an example of information displayed as a result of executing the FLASHCPY
QUERY
command:
FLASHCOPY VOLUME CAPABILITY INFORMATION TABLE
MAXIMUM
EXISTINO ALLOWED RELATIONS
RELATIONS EXCEEDED CAPABILITY
--------- --------- --------- ----------
1 1000 NO SRC CAP
Viewing relationship states of Compatible FlashCopy
69