HP OneView for VMware vCenter User Manual
Page 101
5.
Select the following:
•
Operation: Restart
•
Controller type: Management
•
Controller: A or B, as determined in
6.
Click Restart now.
7.
Log in to the SMU.
8.
Refresh the Storage Module for vCenter cache.
For instructions, see
“Refreshing Storage Module for vCenter data” (page 47)
.
HP XP P9000 virtual disk information missing from Storage Overview page
Possible cause: The hostgroup name for the ports on the array exceeds 16 characters.
Action: Rename the hostgroup on the array to a name that is up to 16 characters, and then initiate
a manual cache refresh. When the refresh process is complete, information will be displayed for
the HP XP P9000 virtual disks.
Concatenated replicated LUNs not recognized as replicated LUNs
Replication information is not available for a datastore that consists of two replicated LUNs.
(
“Concatenated replicated LUNs” (page 101)
).
Figure 19 Concatenated replicated LUNs
Cause: This configuration is not supported by the Storage Module for vCenter.
Duplicate LUNs displayed in Storage Module for vCenter interface
Possible cause: When using multipathing, duplicate LUNs might be displayed if a LUN is presented
to a host using different LUN numbers across multiple paths.
Action: There are two options for addressing this issue:
•
Reconfigure the LUNs so they have a single LUN number across all paths. For more information,
see article 1003973 in the
.
•
Disable the VMware advanced setting Scsi.CompareLUNNumber.
1.
Select a host in the vSphere Client.
2.
Click the Configuration tab.
Troubleshooting the Storage Module for vCenter
101