beautypg.com

HP ProLiant DL760 G2 Server User Manual

Page 281

background image

Troubleshooting Information

Table E-5: Are all of the System Interconnect Status LED Indicators Off?

continued

Refer to “System Interconnect LED Indicators” in Appendix D.

Yes

There is a broken connection between the
I/O board and the power switch.

A power supply problem may exist. The
power supply may not be connected or
inserted properly, may have a damaged
connector, or may have failed.

The system midplane may need to be
replaced.

Check the power source to
verify that an adequate
supply of AC power exists.

Remove the power supply
and check for a damaged
connector. If the connector
appears okay, reinsert the
power supply, firmly and
correctly.

Verify the proper
connection of all power
cables.

Refer to the HP Servers
Troubleshooting Guide
for
further options.

HP ProLiant DL760 Generation 2 Server User Guide

E-13

HP CONFIDENTIAL

Writer: Jennifer Hayward File Name: o-appe Troubleshooting Information.doc