Installing Hardware Options, Hot-Pluggable
To replace DIMMs:
1. Unlock the cartridge and slide it out of the server following the procedure in the
“Removing the Memory Cartridge” section of this chapter.
CAUTION: Do not remove a memory cartridge if the cartridge power LED is
blinking or is solid green. The system will halt.
2. Lift the memory cartridge cover and remove the failed DIMM.
3. Replace the failed DIMM with a working DIMM of the same speed, type, and
size. It should have the same part number (for example 123456-12x, where x is
not required to match).
CAUTION: When handling a memory module, be careful not to touch any of the
contacts. Doing so can damage the module.
NOTE: Be sure memory modules are installed in proper orientation. The modules are
keyed to ensure that they are installed correctly in the memory socket.
4. Be sure that all of the DIMM socket levers are rotated inward before closing the
cartridge cover and then close the memory cartridge cover.
5. Insert the memory cartridge in the server and secure it in place by closing the
cartridge ejector lever.
6. Lock the memory cartridge in place by rotating the cartridge lock clockwise to
the locked position.
7. The system will rebuild and verify the data on the DIMMs in the memory
cartridge as the cartridge power LEDs are blinking. This process is complete
when the cartridge power LED is illuminated solid green, indicating that the
cartridge is online.
8. Continue with normal server operation.