Led indicator state definitions – HP ProLiant DL760 G2 Server User Manual
Page 122

Installing Hardware Options, Hot-Pluggable
LED Indicator State Definitions
Table 5-2 provides descriptions of various LED states.
Table 5-2: Memory Cartridge LED State Definitions
LED Indicator
State
Condition
Action
Solid Cartridge
online
(normal)
None
Off
Cartridge not online
Lock cartridge or check
other LEDs
DIMM Status LED
(amber)
Blinking with cartridge
power LED solid
DIMM installed but not
available to operating
system (hot-add
hot-upgrade in
progress)
Complete hot-add or
hot-upgrade operation
on remaining cartridges
Cartridge Power
LED (green)
Blinking
Cartridge rebuild and
verify in progress
Wait until LED stops
blinking
Off Normal
None
Solid
Cartridge bus failure
Refer to the HP
ProLiant DL760
Generation 2
Maintenance and
Service Guide
Blinking with cartridge
power LED off
Power fault detected
Replace cartridge or
shorted DIMM
Cartridge
Attention LED
(amber)
Blinking with cartridge
power LED solid (alarm
sounds)
Cartridge online but
unlocked (other
cartridges may need
attention)
Lock cartridge and do
not remove
Off Normal
None
Solid
ECC error
Replace DIMM(s)
Blinking DIMM
configuration
error
Remove cartridge and
fix error
HP ProLiant DL760 Generation 2 Server User Guide
5-7
HP CONFIDENTIAL
Writer: Bryce Miller File Name: f-ch5 Installing Options-Hot Pluggable.doc
Codename: Comet Part Number: 201264-001 Last Saved On: 6/17/03 9:47 AM