beautypg.com

Non-raid memory support, Non-raid memory support -23 – HP ProLiant DL760 G2 Server User Manual

Page 138

background image

Installing Hardware Options, Hot-Pluggable

Non-RAID Memory Support

Non-RAID memory configuration is now more user-friendly in the ProLiant DL760
Generation 2 Server with SmartStart 6.4 and ROM dated 4/21/03 and higher.

CAUTION: Running the system in non-RAID memory configuration leaves the
system unprotected from multi-bit errors.

IMPORTANT: You cannot perform a hot replace, hot add, or hot upgrade of memory if the
system is in a non-redundant memory configuration. The system must have a redundant
memory configuration (five cartridges online and error free) before a hot replace, hot add, or
hot upgrade will function.

NOTE: To maintain proper airflow, all five memory cartridges must be installed, whether
running in redundant or non-redundant configuration mode.

To place the server in non-RAID memory configuration mode:

1. Remove the recommended memory cartridge. Refer to “Removing the Memory

Cartridge” in this chapter.

NOTE: If the server is run in non-RAID memory configuration mode, it is recommended
that the memory be removed from the fifth cartridge.

2. Open the memory cartridge and remove all DIMMs. Refer to “Opening the

Memory Cartridge” in this chapter.

3. Reinstall the memory cartridge. The server will detect that no memory is

available in cartridge five and will automatically turn off the appropriate
cartridge LEDs.

To return to a redundant RAID memory configuration, add DIMMs of the same type
and configuration as those installed in the other four cartridges to the empty
cartridge.

HP ProLiant DL760 Generation 2 Server User Guide

5-23

HP CONFIDENTIAL

Writer: Bryce Miller File Name: f-ch5 Installing Options-Hot Pluggable.doc

Codename: Comet Part Number: 201264-001 Last Saved On: 6/17/03 9:47 AM