beautypg.com

Fc-64 director (mcdata) switch, Fc-64 director (mcdata) switch 96 – HP Tape Library Interface Manager Software User Manual

Page 96

background image

96 SAN Environments

Chapter 4

Figure 28

Fibre Channel Switch Configuration

FC-64 Director (McData) Switch

Use the default mode for the FC-64 switch in SAN backup configurations.
You must make the following changes to the default configuration:
1. The FC-64 Fibre Channel switch does not support public or private loop

connections. All devices must use login as N_port only.

2. Set the Interface Manager Hard ALPA setting to [NO] and the Fibre

Channel port mode to [N_port].

3. Set the addressing to [Soft] on internal Fibre Channel cards.

switch59:admin> version
Kernel: 5.3.1
Fabric OS: v2.1.9f
Made on: Mon Dec 4 14.37.39 PST 2000
Flash: Mon Dec 4 14.38.10 PST 2000
BootProm: Thu Jun 17 15:20:39 PDT 1999
switch59:admin>
switch59:admin> switchshow
switchName: switch59
switchType: 3.4
switchState: Online
switchRole: Principal
switchDomain: 2
switchId: fffcO2
switchWwn: 10:00:00:60.169.20.24:04
part 0: sw Online F-Port 50:06:0b:00:00:00:79:dO
port 1: sw Online F-Port 50:06:0b:00:00:06:d4:96
port 2: sw Online F-Port 50:06:0b:00:00:06:d3:dc
port 3: -- No-Module
port 4: -- No-Module
port 5: -- No-Module
port 6: id Online F-Port 10:00:00:e0:02:21:b9:a2
port 7: -- No-Module
switch59:admin>
switch59:admin> qlShow
Switch is not in Quick Loop mode.
switch59:admin>
switch59:admin> zoneShow
Defined configuration:
no configuration defined

Effective configuration,
no configuration in effect

switch59:admin>