Select [2] to default both sets of settings, Select [0] to abort this operation – HP Tape Library Interface Manager Software User Manual
Page 52
52 Management Operations
Chapter 3
When these parameters are changed by the Telnet interface, the request to
change them is immediately sent to the Fibre Channel interface card that has
been selected using menu [Item 1]. However, the new setting does not take
effect until the power is cycled on the Interface Manager or until the interface
card is rebooted. The card selected can be rebooted using the Telnet interface
by selecting [Item 7] in the Fibre Channel Configuration menu.
Caution
When restarting, an interface card will stop any data flowing
through that card, so any backup in progress will fail.
Factory Defaults for the Fibre Channel Interface Card
To set a Fibre Channel interface card configuration back to factory defaults,
three choices are given when [Item 6] is selected from the Fibre Channel
Configuration menu.
Caution
Restarting an interface card will stop any data flowing through
that card, so any backup is progress will fail.
To change configurations back to factory defaults, do the following:
1. Select [1] to default the Interface Settings. These refer to the settings that
control interaction between the Fibre Channel port and the SCSI ports.
2. Select
[3] to default the Management Settings. These refer to parameters
that control how the interface card communicates with the controller card
and the RMC inside the Interface Manager.
3. Select
[2] to default both sets of settings.
4. Select [0] to abort this operation.
The default parameters do not take effect until the power is cycled on the entire
Interface Manager or until the interface card is rebooted. The card selected
can be rebooted using the Telnet interface by selecting [Item 7] in the Fibre
Channel Configuration menu.