50 Management Operations
Chapter 3
Note
The upper right LED will turn green on the interface card long
before the interface card is ready to communicate with the RMC.
It may takes several minutes before the interface card is ready to
report its status back to the RMC.
11. Wait until the interface card boots up and reports its status to the RMC.
The upper right LED will turn green on the interface card long before the
interface card is ready to communicate with the RMC. It may takes several
minutes before the interface card is ready to report its status back to the
RMC.
12. Via Telnet, confirm that the drives are detected by the FC interface card. To
refresh the table shown under the Interface Card menu, select [Enter].
13. Via Telnet, correctly set the FC addressing mode for the new card (see
on page 43, or
14. Plug in the fibre cable.
15. Via Telnet, check that the card has an appropriate FC connection and
address.
— To refresh the table shown under the Interface Card menu, select
[Enter]. The table above the Interface Card menu will show the interface
card’s Fibre Connection status when the interface card is available to
be configured.