beautypg.com

HP OneView for VMware vCenter User Manual

Page 96

background image

1.

Log in to the SMU interface of the MSA2000 G2 or P2000 G3 MSA array as a user with
Manage access. Use the available management IP address (for example:
http://Management_IP_address

).

2.

Select Configuration

→Services→Management.

3.

Clear the Storage Management Initiative Specification (SMI-S) check box, and then click Apply.

4.

Select the Storage Management Initiative Specification (SMI-S) check box, and then click Apply.

The SMI-S service is now running.

5.

Refresh the Storage Module for vCenter data.

For instructions, see

“Refreshing Storage Module for vCenter data” (page 43)

.

Action 2: Restart the MSA2000 G2 or P2000 G3 MSA array management controller.

IMPORTANT:

This procedure restarts the MSA2000 G2 or P2000 G3 array controller. If you

restart a management controller, communication with it is lost until it restarts successfully . This will
not affect disk access. If the restart fails, the partner management controller remains active with
full ownership of operations and configuration information. Other applications (such as Microsoft
VSS and VDS) that rely on the management controller services might be affected.

1.

Log in to the SMU interface of the MSA2000 G2 or P2000 G3 MSA array as a user with
Manage access. Use the available management IP address (for example:
http://Management_IP_address

).

2.

Select Configuration

→System Settings→Network Interfaces.

3.

Determine which controller has the IP address used in

Step 1

.

4.

Select Tools

→Shutdown or Restart Controller.

5.

Select the following:

Operation: Restart

Controller type: Management

Controller: A or B, as determined in

Step 3

6.

Click Restart now.

7.

Log in to the SMU.

8.

Refresh the Storage Module for vCenter data.

For instructions, see

“Refreshing Storage Module for vCenter data” (page 43)

.

P9000 virtual disk information missing from Storage Overview page

Possible cause: The hostgroup name for the ports on the array exceeds 16 characters.

Action: Rename the hostgroup on the array to a name that is up to 16 characters, and then initiate
a manual data refresh. When the refresh process is complete, information will be displayed for
the P9000 virtual disks.

Concatenated replicated LUNs not recognized as replicated LUNs

Replication information is not available for a datastore that consists of two replicated LUNs.
(

“Concatenated replicated LUNs” (page 97)

).