Error codes, Error codes -14 – HP Compaq t5510 Thin Client User Manual
Page 178
9-14
IBM 3270 Emulation
3. Use the Left or Right cursor keys to move the cursor one character position at a
time through the macro, or the Up or Down cursor keys to move 20 character
positions at a time.
4. If required, press the Insert key to toggle between Insert and Edit mode, as
indicated in the status line.
5. Make the required changes to the macro.
6. To save the edit, press Alt + F3.
7. Press Quit to exit.
Error Codes
The following error codes may appear on the status line if an error occurs during
recording or playback.
9001
Exceeded the maximum number of allowed keystrokes.
Remedy: Press the Record key to exit Record mode. To record a new
keystroke sequence, either:
a) Press the Record key and the target Fn key that has erasable data, then
enter the new data.
b) Press the Record key and the target Fn key that has erasable data, then
press the Delete key to erase the recorded data for that key.
9003
You pressed an invalid Fn key while performing the Record or Play
function.
Remedy: Press the Reset key.
9007
You pressed an invalid sequence key (e.g. Play) while performing the
Record function.
Remedy: Press the Reset key.
9010
While performing the Play function, you pressed an Fn key that does not
have a keystroke assigned to it.
Remedy: Press the Reset key.
9015
In communication mode, you pressed either the Quit or Pause key.
Remedy: Press the Reset key.