Installing more than the required number of fans in a single-processor configuration is not a

supported configuration.
For a dual-processor configuration, six fans are required for redundancy. A fan failure or missing fan

causes a loss of redundancy. A second fan failure or missing fan causes an orderly shutdown of the

server.
The server supports variable fan speeds. The fans operate at minimum speed until a temperature

change requires a fan speed increase to cool the server. The server shuts down during the following

temperature-related scenarios:

At POST and in the OS, HP iLO performs an orderly shutdown if a cautionary temperature level

is detected. If the server hardware detects a critical temperature level before an orderly

shutdown occurs, the server performs an immediate shutdown.

When the Thermal Shutdown feature is disabled in RBSU, HP iLO does not perform an orderly

shutdown when a cautionary temperature level is detected. Disabling this feature does not

disable the server hardware from performing an immediate shutdown when a critical

temperature level is detected.

CAUTION:

A thermal event can damage server components when the Thermal Shutdown

feature is disabled in RBSU.