beautypg.com

Hot-plug fans – HP DL380z Gen8 Virtual Workstation User Manual

Page 22

background image

1 – Amber

2 - Green

3 - Green

Interpretation

Flashing 1 Hz

On

Off

An overtemperature

condition exists.

Flashing 2 Hz

Flashing 2 Hz

Off

The capacitor pack is not

attached.

Flashing 2 Hz

Flashing 2 Hz

On

The capacitor has been

charging for 10 minutes, but

has not reached sufficient

charge to perform a full

backup.

On

On

Off

The current backup is

complete, but power

fluctuations occurred during

the backup.

On

On

On

The cache module

microcontroller has failed.

Hot-plug fans

CAUTION:

To avoid damage to server components, fan blanks must be installed in fan bays 1 and

2 in a single-processor configuration.
The only two valid fan configurations are listed in the following table.

Configuration

Fan bay 1

Fan bay 2

Fan bay 3

Fan bay 4

Fan bay 5

Fan bay 6

1 processor

Fan blank

Fan blank

Fan

Fan

Fan

Fan

2 processors

Fan

Fan

Fan

Fan

Fan

Fan

For a single-processor configuration, four fans and two blanks are required in specific fan bays for

redundancy. A fan failure or missing fan causes a loss of redundancy. A second fan failure or missing

fan causes an orderly shutdown of the server.

16 Chapter 2 Component identification