Hot-plug fans – HP DL380z Gen8 Virtual Workstation User Manual
Page 22

1 – Amber
2 - Green
3 - Green
Interpretation
Flashing 1 Hz
On
Off
An overtemperature
condition exists.
Flashing 2 Hz
Flashing 2 Hz
Off
The capacitor pack is not
attached.
Flashing 2 Hz
Flashing 2 Hz
On
The capacitor has been
charging for 10 minutes, but
has not reached sufficient
charge to perform a full
backup.
On
On
Off
The current backup is
complete, but power
fluctuations occurred during
the backup.
On
On
On
The cache module
microcontroller has failed.
Hot-plug fans
CAUTION:
To avoid damage to server components, fan blanks must be installed in fan bays 1 and
2 in a single-processor configuration.
The only two valid fan configurations are listed in the following table.
Configuration
Fan bay 1
Fan bay 2
Fan bay 3
Fan bay 4
Fan bay 5
Fan bay 6
1 processor
Fan blank
Fan blank
Fan
Fan
Fan
Fan
2 processors
Fan
Fan
Fan
Fan
Fan
Fan
For a single-processor configuration, four fans and two blanks are required in specific fan bays for
redundancy. A fan failure or missing fan causes a loss of redundancy. A second fan failure or missing
fan causes an orderly shutdown of the server.
16 Chapter 2 Component identification