8

-18

It is recommended that you write down the settings for respective camera functions. If you have forgotten the settings and

want to set the camera from the beginning, restore the factory default settings first.

*For factory default settings, see p. 8-20.

Restoring the Initial Setting from the
Maintenance Page in the Web Browser

To display the settings menu, you need to enter the IP

address of the camera, user name and administrator

password (p. 4-2).

The maintenance page appears.

A confirmation message appears, asking if you want

to restore the default settings. To restore the default

settings, click [OK].

The camera will be reset to the factory default settings

excluding the following items.

Administrator password for the camera

Maximum packet size

Network settings

Date, time and time zone

SSL certificate

Encrypted communications

Restoring Factory Default Settings with
the Reset Switch on the Camera

If you have forgotten or don't know the IP address of the

camera or your Administrator password, you cannot

operate the camera via the network. In this case, press

the reset switch at the back of the camera.

For dome case removal, see the “Installation Guide.”

There is no on/off switch on the camera. Turn the

camera on and off by plugging in or unplugging LAN

cable (PoE power supply), AC adapter, or external

power plug.

The reset switch is located in a recessed area. Push

the switch using the tip of a slender object such as a

clip.

All settings of the camera, except for the date and

time, are restored to factory default settings.

Restore Settings

1

Launch the web browser and display the settings
menu.

2

On the Setting Menu page, click [Maintenance].

3

Click [Exec] under [Restore Settings].

Caution

• You must not turn off the camera while it is

performing the [Restore Settings] operation.

Turning off the camera at this stage may result in
disabling its ability to boot correctly.

• Once [OK] is clicked, you can no longer stop the

process of restoring the default settings.

1

For VB-M600D/VB-M600VE, remove the dome case.

2

Turn off the camera.

3

Turn on the power while pushing the reset switch, and
keep pushing the reset switch for 5 seconds or more.