Parameter
{factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter set
P607
[-01]
...
[-05]
Ratio
(Ratio)
SK 530E and
above
S
-65000 ... 65000
{ all 1 }
[-01] = Incremental encoder
[-02] = Absolute encoder
[-03] = Setpoint and actual values
[-04] = Universal encoder
[-05] = Synchronous operation
The speed ratio is set for incremental and absolute encoders.
This is also effective for synchronous control (Master- Slave, P610).
ratio
Reduction
Ratio
Speed
n
n
G
M
NOTE:
For further information please refer to section 3.5.
P608
[-01]
...
[-05]
Reduction Ratio
(Reduction Ratio)
SK 530E and
above
S
P
1 ... 65000
{ all 1 }
[-01] = Incremental encoder
[-02] = Absolute encoder
[-03] = Setpoint and actual values
[-04] = Universal encoder
[-05] = Synchronous operation
The speed reduction ratio is set for incremental and absolute encoders.
This is also effective for synchronous control (Master- Slave, P610).
ratio
Reduction
Ratio
Speed
n
n
G
M
NOTE: For further information please refer to Section 3.5.
P609
[-01]
...
[-03]
Offset Position
(Offset position)
SK 530E and
above
S
-
50000,000 …
50000,000 rev.
{ all 0 }
[-01] = Incremental encoder
[-02] = Absolute encoder (CANopen
[-03] = Universal encoder
Here, an independent offset value for absolute and relative position specifications
can be set for
all encoder systems used.