5 positioning – NORD Drivesystems BU0510 User Manual
Page 50
POSICON position control for NORD frequency inverters, SK 530E and above
50
Subject to technical alterations
BU 0510 GB-3911
4.5 Positioning
Parameter
{factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter set
P600
Position Control
(Position control)
SK 530E and
above
S
P
0 ... 4
{ 0 }
Activation of positioning control (see also Section 3.6).
0 = Off, positioning control is disabled
1 = Linear ramp (Max. freq.),
positioning control using linear ramp with maximum
frequency
2 = Linear ramp (setpoint freq.),
positioning control using linear ramp with setpoint
frequency
3 = S-Ramp (Max. freq.),
positioning control using S-ramp with maximum
frequency
4 = S-Ramp (Setpoint freq.),
positioning control using S-ramp with setpoint
frequency
P601
Actual position
(Actual position)
SK 530E and
above
-
50000,000 …
50000,000 rev.
Shows the actual position.
P602
Act. Ref. position
(Actual setpoint position)
SK 530E and
above
-
50000,000 …
50000,000 rev.
Shows the actual setpoint position.
P603
Curr. position diff.
(Actual position difference)
SK 530E and
above
S
-
50000,000 …
50000,000 rev.
Shows the actual difference between the setpoint and actual position.