4 parameter settings, 1 operating display, Parameter settings – NORD Drivesystems BU0510 User Manual
Page 36
POSICON position control for NORD frequency inverters, SK 530E and above
36
Subject to technical alterations
BU 0510 GB-3911
4 Parameter settings
For a detailed overview of all available parameters, please refer to the frequency inverter manual BU0500. The
following only lists selected parameters and parameters specific to the function of POSICON.
NOTE:
The structure of individual parameters for SK 53xE frequency inverters differs from those for the
SK 54xE version. Because of this, the relevant parameters descriptions are listed twice.
Abbreviations used:
FI = Frequency inverter
SW = Software version stored in P707.
S = Supervisor parameters are visible or hidden dependent on P003.
4.1 Operating display
Parameter
{factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter set
P001
Select of disp. value
(Selection of display value)
0 ... 65
{ 0 }
Selection of the operating display for a ControlBox /SimpleBox. (Illustration of functions relevant to
POSICON)
16 = Position setpoint Actual setpoint (setpoint position)
17 = Actual position: Actual position
50 = Actual position, incremental: Actual position value of incremental encoder
51 = Actual position, absolute or Actual position, CANopen: Actual position value of
CANopen absolute encoder
52 = Actual position difference Actual difference between setpoint and actual position
53 = Actual position difference, absolute/incremental: Actual position difference (see also
P631) between absolute encoder and incremental encoder
54 = Actual position difference, calculated/measured: Actual position difference (see also
P630) between the calculated and measured difference of an encoder
55 = Actual position value, universal encoder: Actual position value of universal encoder
(absolute encoders except CANopen) (SK540E and above)