POSICON position control for NORD frequency inverters, SK 530E and above
44
Subject to technical alterations
BU 0510 GB-3911
Value Function
Description
Signal*
20
Referenz
Reference point is available / has been saved
High
21
Position reached
Setpoint position has been reached
High
22
Comparative position
Position value in P626 has been reached
High
23
Comparative position
value
Position value in P262 without consideration of sign has been reached
High
24
Position array value
A value set in P613 has been reached or exceeded.
High
25
Comparative position
reached
Comparative position has been reached, as for 22 with consideration of
P625
High
26
Comparative position
value reached
Comparative position value has been reached, as for 23 with
consideration of P625
High
27
Drive in synchronous
operation
The slave drive has completed the start phase of the "Flying Saw"
function and is now synchronised with the master axis.
High
* For relay contacts (High = "Contact closed", Low = "Contact open")
Parameter
{factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter set
P441
Relay 2 function
(Function of output 2 (Relay 2
– MFR1))
up to SK 535E
P
0 ... 39
{ 7 }
Control terminals 3/4: Functions are identical to P434!
P450
Relay 3 function
(Function of output 3 (DOUT1)
)
From SK 520E
to SK 535E
P
0 ... 39
{ 0 }
Control terminals 5/40: Functions are identical to P434! Digital output, 15V against DGND (for
SK 5x5E devices, deviations of the signal level are possible (see BU0500)).
P455
Relay 4 function
(Function of output 4 (DOUT2))
From SK 520E
to SK 535E
P
0 ... 39
{ 0 }
Functions are identical to P434! Digital output, 15V against DGND (for SK 5x5E devices,
deviations of the signal level are possible (see BU0500)).