POSICON position control for NORD frequency inverters, SK 530E and above

40

Subject to technical alterations

BU 0510 GB-3911

Parameter
{factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter

set

P405

Analog input 2 function

(Analog input 2 function)

up to SK

535E

P

0 ... 82

{ 0 }

This parameter is identical to P400.

P418

Analog output 1 function

(Analog output 1 function)

up to SK

535E

P

0 ... 52

{ 0 }

Analog functions (max. load: 5mA analog, 20mA digital):

An analog voltage (0 ... +10 Volt) can be taken from the control terminals (max. 5mA). Various
functions are available, whereby:

0 Volt analog voltage always corresponds to 0% of the selected value.

10 V always corresponds to the motor nominal values (unless otherwise stated) multiplied by the
P419 standardisation factor, e.g.:

100%

P419

value

nominal

Motor

10Volt

The possible functions are listed in the following tables.

P418

[-01]

...

[-03]

Analog output func.

(Analog output function)

SK 540E and

above

P

0 ... 52

{ all 0 }

[-01] = Analog output: analog output integrated into the FI

[-02] = First IOE, "External analog output of first IOE": Analog output 1 of thefirst IO

extension (SK xU4-IOE)

[-03] = Second IOE, "External analog output of second IOE": Analog output of thesecond IO

extension (SK xU4-IOE)

Analog functions (max. load: 5mA analog, 20mA digital):

An analog voltage (0 ... +10 Volt) can be taken from the control terminals (max. 5mA). Various
functions are available, whereby:

0 Volt analog voltage always corresponds to 0% of the selected value.

10 V always corresponds to the motor nominal values (unless otherwise stated) multiplied by the
P419 standardisation factor, e.g.:

100%

P419

value

nominal

Motor

10Volt

The possible functions are listed in the following tables.

List of possible analog functions for the analog outputs P418
(only POSICON functions)

Value Function

Description

29

Actual position

Within the limits of P615 and P616 the analog output indicates the actual position.