List of possible analog functions for the analog inputs P400 (or P405)
(only POSICON functions)
Value Function
Description
47
Gearing ratio
Gearing ratio. Setting of the gearing ratio between the master and the slave (see
Section 6.5).
58
Setpoint position
Within the limits of P615 and P616, the setpoint position can be specified via the
analog input.
In this case, monitoring of the position for minimum and maximum position is not
performed.
List of possible digital functions for the analog inputs P400 (or P405)
(only POSICON functions)
The analog inputs of the frequency inverter can also be parameterised to process digital signals.
SK
500E … SK 535E
The digital functions are set in the parameter of the relevant analog input (P400 or P404) according to the
following assignment.
SK 540E und SK545E
The digital functions are set in parameter P420 [-08] or [-09].
If a digital function is assigned to an analog input, the analog function of the relevant input must be set to {0}
"Off" in order to prevent misinterpretation of the signals.
A detailed description of the digital functions can
be found after parameters P420 … P425. The functions of the
digital inputs are identical to the digital functions of the analog inputs.
Permissible voltage when using digital functions: 7.5...30V.
NOTE:
The analog inputs with digital functions do not comply with EN61131-2 (Type 1 digital inputs),
because the idling currents are too low.
Value
Function
Value
Function
42
Reference point run
75
Bit 0 PosArr / Inc
43
Reference point
76
Bit 1 PosArr / Inc
44
Teach
– In
77
Bit 2 PosArr / Inc
45
Quit
– Teach – In
78
Bit 3 PosArr / Inc
81
Reset position
82
Sync. position array