3 terminal blocks, sk 535e size 5 and above, Terminal blocks, sk 535e size 5 and above – NORD Drivesystems BU0510 User Manual
Page 10
POSICON position control for NORD frequency inverters, SK 530E and above
10
Subject to technical alterations
BU 0510 GB-3911
2.1.3
Terminal blocks, SK 535E Size 5 and above
X5: digital inputs and
voltage supply*
R
i DIN
approx. 4.5k
Terminal 44
internal
+24V max. 200mA
*no supply!
X6: Incremental encoder
input
Incremental encoder,
e.g.:
10-30V, TTL, RS422
2048 Imp./Rpm.
Note: 5V encoders should
not be used.
.
X7: additional digital inputs
and outputs
DIP switch: left = ON / right = OFF
S4: AIN2:
ON
=
10 Volt
OFF
= 0 … 10 Volt
S3: AIN1:
ON
=
10 Volt
OFF
= 0 … 10 Volt
S2: AIN2:
I
= ON = current 0/4...20mA
V
= OFF = voltage
S1: AIN1:
I
= ON = current 0/4...20mA
V
= OFF = voltage
Note:
If S2 is set to ON (AIN2 = Current input),
S4 must be set to OFF.
If S1 is set to ON (AIN1 = Current input),
S3 must be set to OFF.
X4: analog inputs and
outputs
±10V max. 5mA
-
10V … +10V or
0...10V or 0/4...20mA
Analog output
: 0 … 10V
X11:1x RJ12 socket to
connect the RS232
or RS485 interface
X9/X10: 2x RJ45 socket to
connect the
CAN/CANopen
interface
Fig. 3: Terminal blocks, SK 535E Size 5 and above