NORD Drivesystems BU0280 User Manual
Page 57
5 Parameterisation
BU 0280 GB
Subject to technical amendments
57
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P161
... [-01]
...
...
[-02]
Config. process data for the bus
module
0 ... 1
{ 0 }
[-01] = Inputs
[-02] = Outputs
Possible values which can be set:
0 =
Module does not transmit
1 =
Data length 1 Byte
P162 ...
[-01]
[-02]
...
[-03]
Configuration of FI process data
0 ... 8
{ 0 }
[-01] = Status values
[-02] = Control values
Possible values which can be set:
0 =
FI does not exist
1 =
Data length in Bytes
…
8 =
Data length in Bytes
[-03] = Profile
0 =
AC drive profile 1
1 =
AC drive profile 2
2 =
NORDAC profile
P163 ...
[-01]
[-02]
...
[-03]
Configuration of FI 2 process data
0 ... 8
{ 0 }
[-01] = Status values
[-02] = Control values
Possible values which can be set:
0 =
FI does not exist
1 =
Data length in Bytes
…
9 =
Data length in Bytes
[-03] = Profile
0 =
AC drive profile 1
1 =
AC drive profile 2
2 =
NORDAC profile