Supplementary Manual DeviceNet for NORDAC SK 200E
52
Subject to technical amendments
BU 0280 GB
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P546
…
[-01]
...
…
[-03]
Function Bus setpoint 1 ... 3
S
P
0 ... 24
{ [-01] = 01 }
{ [-02] = 00 }
{ [-03] = 00 }
In this parameter, a function is allocated to the output setpoint during bus actuation.
NOTE:
For further details, please refer to the description for P400.
… [-01] = Bus setpoint value 1
… [-02] = Bus setpoint value 2
(only for PPO Type 2 or 4)
… [-03] = Bus setpoint value 3
(only for PPO Type 2 or 4)
Possible values which can be set:
0 =
Off
1 =
Setpoint frequency (16 bit)
2 =
Frequency addition
3 =
Frequency subtraction
4 =
Minimum frequency
5 =
Maximum frequency
6 =
PI process controller actual value
7 =
PI process controller setpoint
8 =
Actual frequency PID
9 =
Actual PID frequency limited
10 =
Actual PID frequency monitored
11 =
Limiting torque current
12 =
Torque current switch-off limit
13 =
Limiting current
14 =
Current switch-off limit
15 =
Ramp time
16 =
Lead torque (P214) multiplication
17 =
Servo mode torque
18 =
Curve travel calculator
19 =
Digital In bits 0...7
20 =
...24 reserved for Posicon