4.3.4
Class 5 – DeviceNet Connection Object
The settings of the current connection can be read out via this object. The following instances are supported:
Instance 1 = Explicit message
Instance 2 = Polling
Instance 3 = Bit Strobe
Instance 4 = COS/Cyclic
Attr.
Access
Name
Type
Description
1 Get State
USINT
2 Get Instance_type
USINT
3 Get transportClass
trigger
BYTE
4
Get
Produced connection ID
UINT
5
Get
Consumed connection ID
UINT
6
Get
Initial comm. characteristics
BYTE
7
Get
Produced connection size
UINT
8 Get Consumed
connection
size
UINT
9
Get/Set
Expected packet rate
UINT
12
Get
Watchdog timeout action
USINT
13 Get
Produced connection path
length
UINT
14
Get
Produced connection path
EPATH
15 Get
Consumed connection path
length
UINT
16
Get
Consumed connection path
EPATH
17
Get
Production inhibit time
UINT
4.3.5
Class 40 – Motor Data Object
Attr.
Access
Name
Type
Description
3 Get Motor
type USINT
Motor type. Only type 7 = Asynchronous motors are
supported
6 Get/Set
RatedCurrent
UINT
Rated
current of motor Unit = 100mA
7 Get/Set
RatedVoltage
UINT
Nominal voltage
Unit = V
8
Get/Set
RatedPower
UDINT
Nominal power
Unit = W
9 Get/Set
RatedFreq UINT
Nominal frequency
Unit = Hz
12
Get
PoleCount
UINT
Number of poles of motor
In Class 40, Instances 1 to 4 are supported, whereby the value of the instance is addressed to the relevant FI
on the system bus. E.g. FI 2 on the system bus is accessed via Instance 2.